Battery Chargers for Diesel Generator, Fire Engine and AMF Panel Standard Power Supply Battery Chargers for VCB Panel, Substation and Railway Batteries BIS Approved DIN RAIL Mounting Power Supplies CE Approved DIN RAIL Mounting Power Supplies DC Power Pack with Battery Backup UnderOver Voltage Protector Uninterruptible Power Supplies (DC UPS)
Image of Board-to-board Connectors

SSM12BIS05(BC)

Product Description

These are industrial grade battery chargers used to charge the batteries with latest CCCV (Constant Current Constant Voltage) topology. They are mostly used in DG panel / AMF panel, Fire Engine Panel etc.

Sr. No. Order Code Voltage Current Dimension (L x W x H) mm
1 SSM24BIS06(BC) 24VDC 06A 173 x 60 x 91
2 SSM24BIS10(BC)(S) 24VDC 10A 230 x 91 x 126.5
3 SSM24BIS15(BC)(S) 24VDC 15A 226 x 98 x 153.5
4 SSM24BIS20(BC)(S) 24VDC 20A 226 x 96 x 151.5
5 SSM2430(BC)(S) 24VDC 30A 291 x 121 x 182
6 SSM2440(BC)(S) 24VDC 40A 350 x 121 x 188

Features

  • Icon of ThunderInput voltage - 150-265VAC*
  • Icon of ThunderFrequency - 45-60Hz
  • Icon of ThunderInrush current - 30A
  • Icon of ThunderAC current consumption - 3A
  • Icon of ThunderInput protection - 3A Subminiature fuse (Time-Lag type)
  • Icon of ThunderTransient surge protection - Yes (varistor)
  • Icon of ThunderFilter - EMI/RFI
  • Icon of ThunderBuffer time >20msec at full load
  • Icon of ThunderEfficiency >80%

Key Industries

  • Icon of ThunderNominal voltage - 12VDC
  • Icon of ThunderVoltage adj. range - 12-15VDC
  • Icon of ThunderNominal current - 05A
  • Icon of ThunderMaximum output power - 75W
  • Icon of ThunderOver voltage protection - Yes, normally works within 16-19VDC
  • Icon of ThunderOver load protection - Yes, normally works within 102-150% of rated nominal current
  • Icon of ThunderShort circuit protection - Yes
Image of Board-to-board Connectors

SSM12BIS10(BC)(S)

Product Description

These are industrial grade battery chargers used to charge the batteries with latest CCCV (Constant Current Constant Voltage) topology. They are mostly used in DG panel / AMF panel, Fire Engine Panel etc.

Output Characteristics

  • Icon of ThunderNominal voltage - 12VDC
  • Icon of ThunderVoltage adj. range - 12-15VDC
  • Icon of ThunderNominal current - 05A
  • Icon of ThunderMaximum output power - 75W
  • Icon of ThunderOver voltage protection - Yes, normally works within 16-19VDC
  • Icon of ThunderOver load protection - Yes, normally works within 102-150% of rated nominal current
  • Icon of ThunderShort circuit protection - Yes
Sr. No. Order Code Voltage Current Dimension (L x W x H) mm
1 SSM24BIS06(BC) 24VDC 06A 173 x 60 x 91
2 SSM24BIS10(BC)(S) 24VDC 10A 230 x 91 x 126.5
3 SSM24BIS15(BC)(S) 24VDC 15A 226 x 98 x 153.5
4 SSM24BIS20(BC)(S) 24VDC 20A 226 x 96 x 151.5
5 SSM2430(BC)(S) 24VDC 30A 291 x 121 x 182
6 SSM2440(BC)(S) 24VDC 40A 350 x 121 x 188

Features

  • Icon of ThunderLatest state of the art current mode PWM controller and MOSFET based design.
  • Icon of ThunderLED indications for AC OK, DC OK and OVP (over voltage protection).
  • Icon of ThunderSMPS fail floating contact for remote signaling.
  • Icon of ThunderSoft start circuit to limit the AC inrush current.
  • Icon of ThunderReliable even at high ambient temperature.
  • Icon of Thunder100% Full load burn-in test.
  • Icon of ThunderBIS Approved.

Specifications

Input Characteristics

  • Icon of ThunderInput voltage - 150-300VAC*
  • Icon of ThunderFrequency - 45-60Hz
  • Icon of ThunderInrush current - 75A
  • Icon of ThunderAC current consumption - 4A
  • Icon of ThunderInput protection - 4A Subminiature fuse (Time-Lag type)
  • Icon of ThunderTransient surge protection - Yes (varistor)
  • Icon of ThunderFilter - EMI/RFI
  • Icon of ThunderBuffer time >20msec at full load
  • Icon of ThunderEfficiency >80%
Image of Board-to-board Connectors

SSM12BIS20(BC)(S)

Product Description

These are industrial grade battery chargers used to charge the batteries with latest CCCV (Constant Current Constant Voltage) topology. They are mostly used in DG panel / AMF panel, Fire Engine Panel etc.

Output Characteristics

  • Icon of ThunderNominal voltage - 12VDC
  • Icon of ThunderVoltage adj. range - 12-15VDC
  • Icon of ThunderNominal current - 20A
  • Icon of ThunderMaximum output power - 300W
  • Icon of ThunderOver voltage protection - Yes, normally works within 16-19VDC
  • Icon of ThunderOver load protection - Yes, normally works within 102-120% of rated nominal current
  • Icon of ThunderShort circuit protection - Yes(Short-term)

Also Available In

Sr. No. Order Code Voltage Current Dimension (L x W x H) mm
1 SSM24BIS06(BC) 24VDC 06A 173 x 60 x 91
2 SSM24BIS10(BC)(S) 24VDC 10A 230 x 91 x 126.5
3 SSM24BIS15(BC)(S) 24VDC 15A 226 x 98 x 153.5
4 SSM24BIS20(BC)(S) 24VDC 20A 226 x 96 x 151.5
5 SSM2430(BC)(S) 24VDC 30A 291 x 121 x 182
6 SSM2440(BC)(S) 24VDC 40A 350 x 121 x 188

Features

  • Icon of ThunderLatest state of the art current mode PWM controller and MOSFET based design.
  • Icon of ThunderLED indications for AC OK, DC OK and OVP (over voltage protection).
  • Icon of ThunderSMPS fail floating contact for remote signaling.
  • Icon of ThunderSoft start circuit to limit the AC inrush current.
  • Icon of ThunderReliable even at high ambient temperature.
  • Icon of Thunder100% Full load burn-in test.
  • Icon of ThunderBIS Approved.

Specifications

Input Characteristics

  • Icon of ThunderInput voltage - 180-265VAC*
  • Icon of ThunderFrequency - 45-60Hz
  • Icon of ThunderInrush current - 75A
  • Icon of ThunderAC current consumption - 34A
  • Icon of ThunderInput protection - 4A Subminiature fuse (Time-Lag type)
  • Icon of ThunderTransient surge protection - Yes (varistor)
  • Icon of ThunderFilter - EMI/RFI
  • Icon of ThunderBuffer time >20msec at full load
  • Icon of ThunderEfficiency >80%

Let’s Build Something Powerful Together!

Get in touch today for customized electrical and hardware solutions that drive your business forward.